Removal of Counts : NaOH Method
-
Removal of Counts : NaOH Method
- Unwrap the membranes and stack them in a pile (Do not dry
out the membranes completely).
- Place them individually into 1L 0.1 N NaOH 0.2 % SDS wash
solution for exactly 20 min.
- Pour off the wash solution and neutralize with 1 L 0.5 M Tris
(pH 7.5)
0.2 % SDS for 20 min.
- Place the membranes on 3 MM paper. Let dry completely between
two sheets of 3MM paper and store in plastic bag at 4 C.