Removal of Counts : NaOH Method

Removal of Counts : NaOH Method

  1. Unwrap the membranes and stack them in a pile (Do not dry out the membranes completely).
  2. Place them individually into 1L 0.1 N NaOH 0.2 % SDS wash solution for exactly 20 min.
  3. Pour off the wash solution and neutralize with 1 L 0.5 M Tris (pH 7.5) 0.2 % SDS for 20 min.
  4. Place the membranes on 3 MM paper. Let dry completely between two sheets of 3MM paper and store in plastic bag at 4 C.